loading

FREQUENTLY ASKED QUESTIONS

Q: HOW DO I CHECK THE PRESSURE RELIEF VALVE(S)?

A: Pull the ring(s) on the pressure relief valve(s) daily to ensure that it is operating properly and to clear the valve of any possible obstructions. If the valve is stuck or does not operate smoothly, it must be replaced with the same pressure and CFM rated valve.

Q: HOW DO I TEST FOR LEAKS?

A: By creating an account with our store, you will be able to move through the checkout process faster, store multiple shipping addresses, view and track your orders in your account and more. Sed ut perspiciatis unde omnis iste natus error sit voluptatem accusantium.

Q: HOW DO I INSPECT MY PUMP BELT?

A: When inspecting drive belt look for these issues:

  • Cracking
  • Chunks missing
  • Abrasions or tears on sides or back
  • Fraying

If any of these issues are found then belt replacement is recommended.

Q: WHERE DO UNUSUAL NOISES AND VIBRATIONS TYPICALLY COME FROM?

A: Most common noise issues are:

  • Loose Lag screws (Applies to stationary units mounted to the floor)
  • Loose vibration pads
  • Pump knocking
  • Loose bolts
  • Misaligned belt and flywheel
  • Loose Belt guard

Please contact customer service is additional help is needed.